Normal/Reversed Phase Columns

Normal/Reversed Phase Columns

P/N: 960-04021
Regular price $870.00 USD
Sale price $870.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04020
Regular price $780.00 USD
Sale price $780.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04019
Regular price $700.00 USD
Sale price $700.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04018
Regular price $620.00 USD
Sale price $620.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04014
Regular price $980.00 USD
Sale price $980.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04012
Regular price $850.00 USD
Sale price $850.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04011
Regular price $770.00 USD
Sale price $770.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04010
Regular price $690.00 USD
Sale price $690.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 960-04009
Regular price $620.00 USD
Sale price $620.00 USD
Regular price
Unit price
per 
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 03610-01210
Regular price $14,940.00 USD
Sale price $14,940.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01209
Regular price $9,560.00 USD
Sale price $9,560.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01108
Regular price $7,120.00 USD
Sale price $7,120.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01107
Regular price $4,560.00 USD
Sale price $4,560.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01106
Regular price $3,100.00 USD
Sale price $3,100.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01105
Regular price $2,150.00 USD
Sale price $2,150.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01104
Regular price $1,500.00 USD
Sale price $1,500.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01103
Regular price $1,460.00 USD
Sale price $1,460.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01102
Regular price $1,330.00 USD
Sale price $1,330.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01101
Regular price $1,100.00 USD
Sale price $1,100.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 03610-01100
Regular price $1,000.00 USD
Sale price $1,000.00 USD
Regular price
Unit price
per 
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: 00360-04044
Regular price $430.00 USD
Sale price $430.00 USD
Regular price
Unit price
per 
Welchrom Vantage C18 column features moderate carbon loading and specific surface area, offering excellent separation performance and superior batch-to-batch reproducibility, making it ideal for ro...
P/N: 00360-04043
Regular price $400.00 USD
Sale price $400.00 USD
Regular price
Unit price
per 
Welchrom Vantage C18 column features moderate carbon loading and specific surface area, offering excellent separation performance and superior batch-to-batch reproducibility, making it ideal for ro...
P/N: 00360-04041
Regular price $380.00 USD
Sale price $380.00 USD
Regular price
Unit price
per 
Welchrom Vantage C18 column features moderate carbon loading and specific surface area, offering excellent separation performance and superior batch-to-batch reproducibility, making it ideal for ro...
P/N: 00320-02051
Regular price $700.00 USD
Sale price $700.00 USD
Regular price
Unit price
per 
Welchrom series HPLC column is an economical column with excellent peak shape and low column pressure. It adopts the type B fully porous spherical silica (purity>99.999%) and Welch's unique bond...

Column Specifications

C18 Columns

Series Column pH Range Max Temperature Max Pressure Tolerance
Ultisil Series Ultisil LP-C18 0.5-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Ultisil LP-Aq 1.0-8.0
Ultisil XB-C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil AQ-C18 2.0-8.0
Ultisil Plus C18 2.0-8.0
Ultisil Alk C18 2.0-8.0
Ultisil PAH 2.0-8.0
Ultisil Polar RP 2.0-8.0
Ultisil ODS-3 2.0-8.0
Ultisil XS-C18 2.0-8.0
Ultisil Plus LP-C18 0.5-8.0
Xtimate Series Xtimate C18 1.0-12.5 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Xtimate Polar RP 1.0-12.5
Blossmate Series Blossmate C18 2.0-8.0 60 °C 40 MPa
Blossmate Aqs C18 2.0-8.0
Blossmate ST-C18 1.0-11.0
Topsil Series Topsil C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa
Welchrom Series Welchrom C18 2.0-8.0 60 °C 40 MPa
Welchrom Vantage C18 2.0-8.0 60 °C 40 MPa
Boltimate Series Boltimate C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
60 MPa
Boltimate EXT-C18 1.5-12.0
Boltimate LP-C18 1.0-8.0

  C8, C4, C3, C1 and Phenyl Columns

Series Column pH Range Max Temperature Max Pressure Tolerance
Ultisil Series Ultisil XB-C8 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Ultisil LP-C8 1.0-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil F-C8 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil Plus-C8 2.0-8.0
Ultisil XB-Phenyl 2.0-8.0
Ultisil Phenyl-Ether 2.0-8.0
Ultisil PFP 2.0-8.0
Ultisil Plus-phenyl 2.0-8.0
Ultisil XB-C4 2.0-8.0
Ultisil LP-C3 1.0-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil XB-C30 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil XB-C1 2.0-8.0
Ultisil XB-CN 2.0-8.0
Ultisil LP-CN 1.0-8.0
Xtimate Series Xtimate C8 1.0-12.5 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Xtimate Phenyl-Hexyl 1.0-12.5
Xtimate C4 1.0-12.5
Blossmate Series Blossmate C4 2.0-8.0 60 °C 40 MPa
Blossmate Phenyl 2.0-8.0
Topsil Series Topsil C8 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa
Topsil phenyl-Hexyl 2.0-8.0
Topsil CN 2.0-8.0
Welchrom Series Welchrom C8 2.0-8.0 60 °C 40 MPa
Boltimate Series Boltimate C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
60 MPa
Boltimate Phenyl-Hexyl 2.0-8.0
Boltimate EXT-C18 1.5-12
Boltimate EXT-PFP 1.5-10
Boltimate HILIC 2.0-8.0
Boltimate LP-C18 1.0-8.0
Boltimate C8 2.0-8.0
Boltimate Phenyl 2.0-8.0

  Normal-Phase Columns

Series Column pH Range Max Temperature Max Pressure Tolerance
Ultisil Series Ultisil SiO2 2.0-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Ultisil Diol 2.0-8.0
Ultisil XB-NH2 2.0-8.0
Ultisil XB-CN 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Topsil Series Topsil Silica 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa
Topsil NH2 2.0-8.0