The Ultimate Experience of DLC Columns
- Enhancing the inner surface of the chromatography column with strong hydrophobicity overcomes the adverse effects of the column wall on separation.
- The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation.
- Ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.
Detection of Bovine Serum Albumin
Sample Solution:A precise amount of Bovine Serum Albumin (BSA) was accurately weighed, dissolved in the mobile phase, and diluted to achieve a sample solution in which every 1mL contained 0.1mg of the sample
Conclusion: The Diamond like carbon column exhibited significantly increased response values.
Detection of Dexamethasone sodium phosphate
Conclusion:
1.The diamond column minimizes the specific adsorption behavior of the chromatographic column tube, achieving efficient separation while showing higher sensitivity and response values.
2. The peak signal of the diamond column can be increased several times, indicating that it has obvious advantages in testing metal-sensitive compounds.
Brand: Ultisil
Phase: XS-C18
Particle Size: 5μm
Pore Size: 120Å
USP Classification: L1
Separation Mode: Reversed Mode
pH Range: 2.0-8.0
Surface Area: 320m2/g
Carbon Load: 23%
Max.Pressure: 40Mpa
Endcapped: Yes
Max.Temp.: 60°C(pH≤6.5) and 40°C(pH>6.5)
Particle Shape: Spherical
The Ultimate Experience of DLC Columns
- Enhancing the inner surface of the chromatography column with strong hydrophobicity overcomes the adverse effects of the column wall on separation.
- The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation.
- Ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.
Detection of Bovine Serum Albumin
Sample Solution:A precise amount of Bovine Serum Albumin (BSA) was accurately weighed, dissolved in the mobile phase, and diluted to achieve a sample solution in which every 1mL contained 0.1mg of the sample
Conclusion: The Diamond like carbon column exhibited significantly increased response values.
Detection of Dexamethasone sodium phosphate
Conclusion:
1.The diamond column minimizes the specific adsorption behavior of the chromatographic column tube, achieving efficient separation while showing higher sensitivity and response values.
2. The peak signal of the diamond column can be increased several times, indicating that it has obvious advantages in testing metal-sensitive compounds.
Brand: Ultisil
Phase: XS-C18
Particle Size: 5μm
Pore Size: 120Å
USP Classification: L1
Separation Mode: Reversed Mode
pH Range: 2.0-8.0
Surface Area: 320m2/g
Carbon Load: 23%
Max.Pressure: 40Mpa
Endcapped: Yes
Max.Temp.: 60°C(pH≤6.5) and 40°C(pH>6.5)
Particle Shape: Spherical