Normal/Reversed Phase Columns
P/N: H00207-31941
Ultisil DLC AQ-C18, 5μm, 4.6×150mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00107-23041
Xtimate C4, 5μm, 4.6×150mm, 300Å
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-23043
Xtimate C4, 5μm, 4.6×250mm, 300Å
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-13043
Xtimate C4, 3μm, 4.6×250mm, 300Å
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-13041
Xtimate C4, 3μm, 4.6×150mm, 300Å
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: H00201-11810
Ultisil DLC UHPLC XB-C18, 1.8μm, 2.1×50mm, W-port
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00260-31943
Ultisil DLC Plus C18, 5μm, 4.6×250mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00215-31943
Ultisil DLC Polar RP, 5μm, 4.6×250mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00206-31931
Ultisil DLC Diol, 5μm, 4.0×125mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00201-31937
Ultisil DLC XB-C18, 5μm, 4.6×50mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00207-31943
Ultisil DLC AQ-C18, 5μm, 4.6×250mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00253-31943
Ultisil DLC Alk C18, 5μm, 4.6×250mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation. The high har...
P/N: 00101-21541
Xtimate DLC C18, 5μm, 4.6×150mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00101-21543
Xtimate DLC C18, 5μm, 4.6×250mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00208-31943
Ultisil DLC LP-C18, 5μm, 4.6×250mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00604-21043
Blossmate Polar-Propylamide, 5μm, 4.6×250mm
Blossmate Polar-Propylamide column is a hydrophilic (HILIC) column designed to achieve the separation of large polar drug molecules. Based on ultra high purity and high mechanical strength spherica...
P/N: 00604-21041
Blossmate Polar-Propylamide, 5μm, 4.6×150mm
Blossmate Polar-Propylamide column is a hydrophilic (HILIC) column designed to achieve the separation of large polar drug molecules. Based on ultra high purity and high mechanical strength spherica...
P/N: H00243-31023
Ultisil MM NH2/CN, 5μm, 3.0×150mm
Ultisil MM NH2/CN column features a mixed-mode stationary phase with amino (NH2) and cyano (CN) bonding, providing unique selectivity compared to conventional amino columns. It is particularly suit...
P/N: H00243-31041
Ultisil MM NH2/CN, 5μm, 4.6×150mm
Ultisil MM NH2/CN column features a mixed-mode stationary phase with amino (NH2) and cyano (CN) bonding, providing unique selectivity compared to conventional amino columns. It is particularly suit...
P/N: H00243-31043
Ultisil MM NH2/CN, 5μm, 4.6×250mm
Ultisil MM NH2/CN column features a mixed-mode stationary phase with amino (NH2) and cyano (CN) bonding, providing unique selectivity compared to conventional amino columns. It is particularly suit...
P/N: K310-02043-3P
Welchrom C18, 5μm, 4.6×250mm,3/pk
Welchrom C18 column is an economical option from Welch Materials. With its low column pressure, affordable pricing, and high cost-performance ratio, it outperforms other products in the same price ...
P/N: HK275-31043-3P
Ultisil ODS-3, 5μm, 4.6×250mm,3/pk
Ultisil ODS-3 column is a universal C18 column compatible with 100% aqueous phases. It has minimal adsorption for both acidic and basic compounds, ensuring excellent peak shapes. Ideal for the sepa...
P/N: HK260-31043-3P
Ultisil Plus C18, 5μm, 4.6×250mm,3/pk
Ultisil Plus series features exceptional anti-fouling capability, ensuring outstanding longevity while analyzing complex matrix samples.Ultisil Plus C18 column has a lower specific surface area, sl...
P/N: HK215-31043-3P
Ultisil Polar RP, 5μm, 4.6×250mm,3/pk
Ultisil Polar RP is a reversed-phase column with selectivity distinct from conventional C18. It incorporates embedded polar groups, allowing the alkyl phase to remain solvated even in highly aqueou...
Column Specifications
C18 Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-Aq | 1.0-8.0 | |||
Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil AQ-C18 | 2.0-8.0 | |||
Ultisil Plus C18 | 2.0-8.0 | |||
Ultisil Alk C18 | 2.0-8.0 | |||
Ultisil PAH | 2.0-8.0 | |||
Ultisil Polar RP | 2.0-8.0 | |||
Ultisil ODS-3 | 2.0-8.0 | |||
Ultisil XS-C18 | 2.0-8.0 | |||
Ultisil Plus LP-C18 | 0.5-8.0 | |||
Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Polar RP | 1.0-12.5 | |||
Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Aqs C18 | 2.0-8.0 | |||
Blossmate ST-C18 | 1.0-11.0 | |||
Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate EXT-C18 | 1.5-12.0 | |||
Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil Plus-C8 | 2.0-8.0 | |||
Ultisil XB-Phenyl | 2.0-8.0 | |||
Ultisil Phenyl-Ether | 2.0-8.0 | |||
Ultisil PFP | 2.0-8.0 | |||
Ultisil Plus-phenyl | 2.0-8.0 | |||
Ultisil XB-C4 | 2.0-8.0 | |||
Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C1 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 | |||
Ultisil LP-CN | 1.0-8.0 | |||
Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
Xtimate C4 | 1.0-12.5 | |||
Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Phenyl | 2.0-8.0 | |||
Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil phenyl-Hexyl | 2.0-8.0 | |||
Topsil CN | 2.0-8.0 | |||
Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
Boltimate EXT-C18 | 1.5-12 | |||
Boltimate EXT-PFP | 1.5-10 | |||
Boltimate HILIC | 2.0-8.0 | |||
Boltimate LP-C18 | 1.0-8.0 | |||
Boltimate C8 | 2.0-8.0 | |||
Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil Diol | 2.0-8.0 | |||
Ultisil XB-NH2 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device