
Normal/Reversed Phase Columns
P/N: HK208-31043-3P
Ultisil LP-C18, 5μm, 4.6×250mm,3/pk
Ultisil LP-C18 column is a HPLC column designed to withstand 100% aqueous to 100% organic solvents. It features steric hindrance side-chain protection to shield hydroxyl groups and adopts a non-end...
P/N: HK201-31043-3P
Ultisil XB-C18, 5μm, 4.6×250mm,3/pk
Ultisil XB-C18 is one of the most versatile C18 analytical columns on the market. It features advanced bonding and double-endcapping technology, delivering nearly perfect peak shapes. This column i...
P/N: K101-21043-3P
Xtimate C18, 5μm, 4.6×250mm,3/pk
Xtimate C18 column utilizes Welch's patented organic-inorganic hybrid surface technology to modify the silica gel matrix. Specifically designed for liquid chromatography method development, it allo...
P/N: H00201-11910
Ultisil DLC UHPLC XB-C18, 1.8μm, 2.1×50mm
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00609-31012
Blossmate Phenyl, 3.5μm, 450Å, 2.1×100mm
Blossmate Phenyl is a phenyl column offering enhanced accuracy, faster performance, lower costs, and a broader testing range.
P/N: 00609-31010
Blossmate Phenyl, 3.5μm, 450Å, 2.1×50mm
Blossmate Phenyl is a phenyl column offering enhanced accuracy, faster performance, lower costs, and a broader testing range.
P/N: 00608-31012
Blossmate C4, 3.5μm, 450Å, 2.1×100mm
Blossmate C4 is a C4 column offering enhanced accuracy, faster performance, lower costs, and a broader testing range.
P/N: 00608-31010
Blossmate C4, 3.5μm, 450Å, 2.1×50mm
Blossmate C4 is a C4 column offering enhanced accuracy, faster performance, lower costs, and a broader testing range.
P/N: 00607-21443
Blossmate PSV C18 Plus, 5μm, 4.6×250mm
Blossmate PSV C18 Plus column adopts the integrated design of the guard column and the analytical column. An integrated guard column is added at the front end of the analytical column to protect th...
P/N: 00607-21441
Blossmate PSV C18 Plus, 5μm, 4.6×150mm
Blossmate PSV C18 Plus column adopts the integrated design of the guard column and the analytical column. An integrated guard column is added at the front end of the analytical column to protect th...
P/N: 00603-21043
Blossmate Aqs C18, 5μm, 4.6×250mm
Blossmate Aqs C18 is a reversed-phase chromatography column compatible with pure aqueous and saline phases, suitable for the analysis of highly hydrophilic and strongly polar samples.
P/N: 00602-21043
Blossmate ST-C18, 5μm, 4.6×250mm
Blossmate ST-C18 utilizes specialized surface treatment technology on a silica matrix, maintaining high mechanical strength and column efficiency. It is suitable for analyzing basic samples and met...
P/N: 00601-21043
Blossmate C18, 5μm, 4.6×250mm
Blossmate C18 is a versatile C18 column with broad applicability, ideal for analyzing complex sample components, and delivering excellent reproducibility.
P/N: 00606-21043
Blossmate SAX, 5μm, 4.6×250mm
Blossmate SAX column can be used under the condition of high fow rate and high pressure. It is compatible with ionic strength change of various mobile phase to achieve fast equilibrium and suitable...
P/N: 00606-21041
Blossmate SAX, 5μm, 4.6×150mm
Blossmate SAX column can be used under the condition of high fow rate and high pressure. It is compatible with ionic strength change of various mobile phase to achieve fast equilibrium and suitable...
P/N: 00605-21043
Blossmate PSV C18, 5μm, 4.6×250mm
Blossmate PSV C18 is a newly developed HPLC column which can be compatible with high proportion of aqueous phase. Taking super high purity spherical silica as matrix, it bonded high-density alkyl f...
P/N: 00605-21041
Blossmate PSV C18, 5μm, 4.6×150mm
Blossmate PSV C18 is a newly developed HPLC column which can be compatible with high proportion of aqueous phase. Taking super high purity spherical silica as matrix, it bonded high-density alkyl f...
P/N: 966-04039
Boltimate C8, 2.7μm, 90Å, 4.6×100mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 966-04037
Boltimate C8, 2.7μm, 90Å, 4.6×50mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 966-04021
Boltimate C8, 2.7μm, 90Å, 3.0×100mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 966-04019
Boltimate C8, 2.7μm, 90Å, 3.0×50mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 967-04039
Boltimate Phenyl, 2.7μm, 90Å, 4.6×100mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 967-04037
Boltimate Phenyl, 2.7μm, 90Å, 4.6×50mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
P/N: 967-04021
Boltimate Phenyl, 2.7μm, 90Å, 3.0×100mm
A Boltimate core-shell column is constructed with a 1.7 μm solid core and a 0.5 μm porous layer. This core-shell particle design delivers high column efficiency (~200,000 plates/m) and exceptional ...
Column Specifications
C18 Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-Aq | 1.0-8.0 | |||
Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil AQ-C18 | 2.0-8.0 | |||
Ultisil Plus C18 | 2.0-8.0 | |||
Ultisil Alk C18 | 2.0-8.0 | |||
Ultisil PAH | 2.0-8.0 | |||
Ultisil Polar RP | 2.0-8.0 | |||
Ultisil ODS-3 | 2.0-8.0 | |||
Ultisil XS-C18 | 2.0-8.0 | |||
Ultisil Plus LP-C18 | 0.5-8.0 | |||
Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Polar RP | 1.0-12.5 | |||
Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Aqs C18 | 2.0-8.0 | |||
Blossmate ST-C18 | 1.0-11.0 | |||
Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate EXT-C18 | 1.5-12.0 | |||
Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil Plus-C8 | 2.0-8.0 | |||
Ultisil XB-Phenyl | 2.0-8.0 | |||
Ultisil Phenyl-Ether | 2.0-8.0 | |||
Ultisil PFP | 2.0-8.0 | |||
Ultisil Plus-phenyl | 2.0-8.0 | |||
Ultisil XB-C4 | 2.0-8.0 | |||
Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C1 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 | |||
Ultisil LP-CN | 1.0-8.0 | |||
Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
Xtimate C4 | 1.0-12.5 | |||
Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Phenyl | 2.0-8.0 | |||
Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil phenyl-Hexyl | 2.0-8.0 | |||
Topsil CN | 2.0-8.0 | |||
Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
Boltimate EXT-C18 | 1.5-12 | |||
Boltimate EXT-PFP | 1.5-10 | |||
Boltimate HILIC | 2.0-8.0 | |||
Boltimate LP-C18 | 1.0-8.0 | |||
Boltimate C8 | 2.0-8.0 | |||
Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil Diol | 2.0-8.0 | |||
Ultisil XB-NH2 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device